WAGO

Germany ·36 part numbers · www.wago.com

36 part numbers

Sort by
WAGO
750-303 Fieldbus coupler WAGO 750
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
  • SeriesWAGO-I/O-SYSTEM 750
Quote within 24h Sourced on request
On request
WAGO
750-333 Fieldbus coupler WAGO 750
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
  • SeriesWAGO-I/O-SYSTEM 750
Quote within 24h Sourced on request
On request
WAGO
750-342 Fieldbus coupler WAGO 750
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
  • SeriesWAGO-I/O-SYSTEM 750
Quote within 24h Sourced on request
On request
WAGO
750-352 Fieldbus coupler WAGO 750
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
  • SeriesWAGO-I/O-SYSTEM 750
Quote within 24h Sourced on request
On request
WAGO
750-362 Fieldbus coupler WAGO 750
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
  • SeriesWAGO-I/O-SYSTEM 750
Quote within 24h Sourced on request
On request
WAGO
750-363 Fieldbus coupler WAGO 750
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
  • SeriesWAGO-I/O-SYSTEM 750
Quote within 24h Sourced on request
On request
WAGO
750-455 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-457 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-459 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-469 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-489 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-492 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-496 Analog input module WAGO 750
  • SignalAnalog input
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-550 Analog output module WAGO 750
  • SignalAnalog output
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-554 Analog output module WAGO 750
  • SignalAnalog output
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-555 Analog output module WAGO 750
  • SignalAnalog output
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request
WAGO
750-564 Analog output module WAGO 750
  • SignalAnalog output
  • ApplicationWAGO 750 modular I/O system
  • MountingDIN rail (modular)
Quote within 24h Sourced on request
On request

About WAGO

MT.parts is an independent supplier of WAGO parts, and all 29 items here belong to one line: the WAGO-I/O-SYSTEM 750. 15 I/O modules, 6 fieldbus couplers and gateways, 5 fieldbus controllers, 3 accessories. It is a modular system, not a wide range: what counts is knowing which head station and which modules belong in the same node.

WAGO parts we stock

Four categories, count in brackets, all 750 numbers. Availability is confirmed on quote.

One series, several module classes

Everything here is WAGO-I/O-SYSTEM 750. A node is a head station, modules in physical order, and an end module that terminates the internal data bus.

  • Fieldbus coupler: head station with no program, maps the modules into the master's process image; the protocol is fixed by the part number
  • Fieldbus controller (PFC): head station that runs its own program locally and still reports upstream
  • Digital I/O modules: 24 V DC inputs, 2 to 16 channels, transistor outputs rated per channel, relay modules for higher loads
  • Analog I/O modules: voltage, current, RTD and thermocouple inputs, voltage and current outputs for valves and drive references
  • Special function modules: serial interfaces, counters and similar, each with its own data width
  • Supply and system modules: feed the internal bus or open a new potential group for a separate field supply
  • End module and accessories: the end module that closes the internal data bus, plus jumpers, markers and rail hardware

Condition, testing and warranty

Each item is listed as new, new original surplus, refurbished or used, with the condition on the item page beside the 750 number. Modules are tested in a node before shipping: inserted behind a coupler and checked for bus communication, channel status and diagnostic LEDs; couplers and controllers for boot, addressing and fieldbus link. The cage clamp terminals are inspected too: the spring connection and the module latch are the wear points on a used module.

The 750 series has been in the field for a long time, which is why these requests come in: modules from different years sit in the same node, and an older module number keeps that node and its process image as they are, without a reconfiguration and a download. Every item carries a 12 month MT Parts warranty against functional failure, issued by MT Parts. No WAGO factory warranty applies to surplus, refurbished or used stock.

How to identify the right replacement

  • Protocol first: the head station part number fixes the fieldbus, PROFIBUS, PROFINET, Modbus TCP, EtherNet/IP, CANopen or DeviceNet. A node does not change protocol by configuration.
  • Coupler or controller: a coupler is remote I/O under a master, a PFC runs its own program, and the same modules sit behind either one.
  • Module compatibility: 750 modules share the internal bus, but the head station limits how many modules and how much process data it maps. Count channels and data width before adding.
  • Order and potential groups: the process image follows the modules left to right, so inserting one in the middle shifts every address after it, and a supply module opens a new potential group exactly where it sits.
  • Connection style and width: read the number on the label, not just the function, because WAGO numbers the same function in more than one terminal style. Then check the finished node, end module included, still fits the rail.

FAQ

How do I check whether you have a WAGO 750 part number?

Search the full number from the module label. If it is not among the 29 items listed, send it through Request a quote and we answer in 24 hours, subject to availability.

Will an older 750 module work behind my coupler?

Usually yes: the 750 series keeps one internal bus across generations, but the head station sets the limits, module count and process data width. Send the coupler number and the module list.

Do you supply discontinued 750 modules and older couplers?

Yes, that is the point of this catalog. When a module is out of production, surplus and used units keep the node intact instead of forcing a new head station and a reconfiguration.

Are these WAGO modules new or refurbished?

Declared per unit on the item page: new, new original surplus, refurbished or used. Used modules are pulls that passed a node test, terminals and latch inspected.

Do you ship WAGO parts outside the United States?

Yes, worldwide. The quote includes freight and the documents customs asks for, with HS classification and origin. Items under US export control are screened.

Send the 750 numbers you need, the coupler or controller in the node and the protocol it runs. We answer in 24 hours. Request a quote for WAGO 750 parts.